What is the difference between a junction box and an outlet box?
A junction box houses splices and connections only; an outlet box holds a device (receptacle/switch) or fixture in addition to connections.
What is a knockout and a connector's role on a box?
A knockout is a removable punched circle in a box; a connector secures the cable or conduit into that opening and protects conductors from the box edge.
What is the standard mounting height for a wall receptacle and a switch (typical rule-of-thumb)?
Receptacles are commonly mounted about 12-18 inches to center and switches about 48 inches to center above the finished floor (verify against local code/plans).
What does NEC require for receptacle spacing along habitable room walls?
Receptacles so that no point along the floor line is more than 6 feet from a receptacle (the 6-foot / 12-foot rule), so a 6-foot cord can reach without crossing a doorway.
What is the difference between a single-pole, three-way, and four-way switch?
Single-pole controls a load from one location; three-way switches (used in pairs) control a load from two locations; four-way switches are placed between three-ways to add more control locations.
What is a branch circuit?
The circuit conductors between the final overcurrent device protecting the circuit and the outlet(s) it serves (NEC Article 210).
What is a feeder?
All circuit conductors between the service equipment (or other power source) and the final branch-circuit overcurrent device (NEC Article 215).
What is the continuous-load rule for sizing branch circuits and overcurrent devices?
The conductor and overcurrent device must be sized at not less than 125% of the continuous load (load expected to run 3 hours or more) plus 100% of the noncontinuous load.
What overcurrent device and conductor size are typical for 15A and 20A general lighting branch circuits?
15A circuit uses 14 AWG copper; 20A circuit uses 12 AWG copper.
What is the service entrance?
The conductors and equipment that deliver electrical energy from the utility supply to the wiring system of the premises, ending at the service disconnect.
What is a panelboard?
A single panel or group of panel units with buses and overcurrent devices, designed to be placed in a cabinet and accessible only from the front, that distributes power to branch circuits.
What is the maximum number of service disconnecting means allowed per NEC, and how must they operate?
Up to six disconnects (the historical 'six-throw rule'); each must disconnect all ungrounded conductors with no more than six operations of the hand. (2020 NEC requires them in separate enclosures.)
What is the difference between grounding and bonding?
Grounding connects a system or equipment to the earth; bonding connects metallic parts together to create a low-impedance path so they are at the same potential and can carry fault current safely.
What is the purpose of the grounding electrode conductor (GEC)?
It connects the grounded system conductor and/or equipment grounding system to the grounding electrode (such as a ground rod or building steel).
Where is the main bonding jumper located and what does it do?
In the service equipment; it connects the grounded (neutral) conductor to the equipment grounding system/enclosure, providing the path for fault current to return to the source and trip the overcurrent device.
Why must the neutral and ground be bonded only at the service and kept separate in downstream subpanels?
Bonding only at the service prevents normal neutral current from flowing on equipment grounding conductors and metal enclosures, avoiding parallel paths and shock hazards in subpanels.
What is the function of an overcurrent protection device (fuse or circuit breaker)?
To automatically open the circuit and stop current flow when current exceeds a safe value due to overload, short circuit, or ground fault, protecting conductors and equipment.
What is the difference between an overload and a short circuit?
An overload is current somewhat above rated value on an otherwise sound circuit (e.g., too many loads). A short circuit is a fault between conductors causing very high current; a ground fault is current to ground.
What is the difference between a GFCI and an AFCI?
A GFCI (ground-fault circuit interrupter) protects people by tripping on small current imbalance to ground (about 5 mA). An AFCI (arc-fault circuit interrupter) detects dangerous arcing faults to prevent fires.
What does a transformer do and what is the basic turns/voltage relationship?
It transfers AC energy between circuits by magnetic induction, changing voltage and current levels. Ep/Es = Np/Ns: the voltage ratio equals the turns ratio of primary to secondary windings.
In an ideal transformer, how does current relate to voltage between primary and secondary?
Power in equals power out, so when voltage is stepped down the current is stepped up proportionally (and vice versa): Ep x Ip = Es x Is.
What is the difference between a delta and a wye (star) three-phase transformer connection?
Delta: windings connected end-to-end in a triangle, no neutral typically, line voltage equals phase voltage. Wye: windings share a common neutral point, line voltage equals 1.732 (square root of 3) times phase voltage, and provides a neutral.
In a balanced three-phase wye system, what is the relationship between line and phase voltage?
Line voltage = 1.732 (square root of 3) x phase voltage. For example, 120V phase yields 208V line.
What is a step-down transformer used for in distribution?
To reduce high distribution/transmission voltage to a lower utilization voltage (e.g., 480V to 120/208V) suitable for building equipment and branch circuits.
What this deck covers
The Electrical deck follows the NCCER Certification Electrical syllabus — 4 chapters and 12 topics — so questions land on material that is genuinely examinable rather than trivia around it. That works out to roughly 14.5 cards per chapter.
Answers are written to be recallable, not just readable — averaging about 167 characters, which is long enough to carry the reasoning and short enough to say out loud.
A deck like this earns its keep on the second and third pass. Read the syllabus first so you know the shape of the subject, then use the cards to find the specific facts that have not stuck.
Electrical flashcards FAQ
How many Electrical flashcards are in this NCCER Certification deck?
58 cards. This page previews 24 of them, sampled evenly across the deck so you can judge the difficulty before installing anything.
Are these NCCER Certification flashcards free?
Yes. The preview here is free to read with no signup, and the full 58-card deck is free inside the Examius app.
What do the Electrical cards cover?
They follow the NCCER Certification Electrical syllabus — 4 chapters and 12 topics — so the questions track what is actually examinable.
How should I use these flashcards?
Read the syllabus first so you know the shape of the subject, then drill the deck. Examius schedules each card with spaced repetition, so cards you keep missing come back sooner and ones you know drift further apart.