🇺🇸 Journeyman/Master Electrician License Exam · subject

Journeyman/Master Electrician License Exam Motors, HVAC, and Special Equipment Syllabus

The Motors, HVAC, and Special Equipment syllabus for Journeyman/Master Electrician License Exam in full: 3 chapters, 10 topics and 19 sub-topics, every one listed below, plus 50 Motors, HVAC, and Special Equipment flashcards with answers.

3Chapters
10Topics
19Sub-topics
50Flashcards

Motors, HVAC, and Special Equipment syllabus: all 3 chapters

Expand any chapter to see its topics and sub-topics.

  1. Motor Circuits (Article 430)

    4 topics
    • Motor Conductor Sizing
      • Using FLC tables (Tables 430.247-430.250)
      • 125% of FLC for single-motor branch circuits
    • Motor Overload and Branch-Circuit Protection
      • Overload sizing (115%-125%)
      • Short-circuit/ground-fault device sizing (Table 430.52)
    • Feeders Supplying Multiple Motors
      • Sum of FLCs plus 125% of largest
      • Feeder protection for motor groups
    • Motor Controllers and Disconnects
      • Disconnecting means rating and location
      • Controller marking and sizing
  2. Air Conditioning and Refrigeration (Article 440)

    3 topics
    • Hermetic Motor-Compressor Loads
      • Using rated-load current (RLA) vs. FLC
      • Branch-circuit selection current
    • Disconnecting Means and Overcurrent Protection
      • Disconnect sizing within sight of equipment
      • Minimum circuit ampacity (MCA) and maximum overcurrent protection (MOCP) nameplate use
    • Conductor Sizing for HVAC Equipment
      • Sizing to nameplate MCA
      • Combination loads with electric heat
  3. Transformers and Capacitors (Articles 450 and 460)

    3 topics
    • Transformer Overcurrent Protection
      • Primary-only protection (Table 450.3(B))
      • Primary and secondary protection
    • Transformer Sizing and Conductor Connections
      • Primary and secondary conductor ampacity
      • Transformer vault and installation requirements
    • Capacitor Conductor and Protection Sizing
      • 135% of capacitor rated current

Journeyman/Master Electrician License Exam Motors, HVAC, and Special Equipment flashcards — 50 questions with answers

  1. When sizing the branch-circuit conductors for a single continuous-duty motor, what minimum percentage of the motor full-load current (FLC) must the conductor ampacity equal?

    At least 125% of the motor FLC (NEC 430.22): $I_{conductor} \geq 1.25 \times I_{FLC}$.

  2. For sizing motor branch-circuit conductors, do you use the motor nameplate current or the NEC table FLC value?

    Use the FLC value from NEC Tables 430.247–430.250 (based on horsepower and voltage), NOT the nameplate current. Nameplate (actual FLA) is used only for overload sizing.

  3. A 10 hp, 230 V, 3-phase motor has a table FLC of 28 A. What is the minimum branch-circuit conductor ampacity?

    $1.25 \times 28 = 35$ A minimum conductor ampacity.

  4. Why does the NEC require table FLC values rather than nameplate values for conductor and branch-circuit protection sizing?

    Table values give a standardized, worst-case current so designs remain consistent regardless of the specific motor installed; nameplate current is reserved for sizing the overload (running) protection, which must match the actual motor.

  5. For a continuous-duty motor, what is the conductor ampacity rule and which NEC section governs it?

    NEC 430.22: conductors supplying a single continuous-duty motor must have an ampacity of at least 125% of the motor's table FLC.

  6. What percentage of nameplate FLA is used to size overload protection for a motor with a marked service factor of $1.15$ or greater?

    125% of the nameplate full-load amperes (NEC 430.32).

  7. List the NEC 430.32 overload sizing percentages for the three motor categories.

    Service factor $\geq 1.15$: 125%; temperature rise $\leq 40^{\circ}\text{C}$: 125%; all other motors: 115% of nameplate FLA.

  8. What does motor branch-circuit short-circuit and ground-fault protection (Table 430.52) protect against — and what does it NOT protect against?

    It protects against short circuits and ground faults. It does NOT protect against overloads (running overcurrent); overloads are handled separately by the overload device per 430.32.

  9. Give the standard maximum Table 430.52 percentages of FLC for: nontime-delay fuse, dual-element (time-delay) fuse, instantaneous-trip breaker, and inverse-time breaker.

    Nontime-delay fuse 300%; dual-element (time-delay) fuse 175%; instantaneous-trip breaker 800%; inverse-time breaker 250%.

  10. If the Table 430.52 standard values are not sufficient to allow the motor to start, what increased maximum percentages are permitted?

    Nontime-delay fuse up to 400%; dual-element (time-delay) fuse up to 225%; instantaneous-trip breaker up to 1300%; inverse-time breaker up to 400%.

  11. If the calculated overload device does not allow the motor to start/run without tripping, what next-step maximum percentages does NEC 430.32(C) allow?

    Increase to: service factor $\geq 1.15 \to 140\%$; temperature rise $\leq 40^{\circ}\text{C} \to 140\%$; all others $\to 130\%$ of nameplate FLA.

  12. What is the NEC 430.24 rule for sizing feeder conductors supplying several motors?

    Ampacity must be at least 125% of the highest-rated motor's FLC plus the sum of the FLCs of all other motors on the feeder.

  13. State the formula for the minimum feeder conductor ampacity supplying multiple motors.

    $I_{feeder} = 1.25 \times I_{largest} + \sum I_{other}$, where $I_{largest}$ is the largest motor FLC and $\sum I_{other}$ is the sum of all other motor FLCs.

  14. How is the maximum feeder overcurrent protective device sized for a group of motors (NEC 430.62)?

    It equals the largest branch-circuit OCPD rating of any one motor in the group plus the sum of the FLCs of all the other motors.

  15. Three motors have FLCs of 28 A, 20 A, and 16 A; the largest motor's branch OCPD is 70 A. What is the maximum feeder OCPD, and what standard size is used?

    $70 + 20 + 16 = 106$ A maximum; since you may not exceed the calculated value, use the next standard size down: a 100 A device.

  16. What is the minimum ampere rating of a motor disconnecting means relative to the motor's full-load current (NEC 430.110)?

    At least 115% of the motor full-load current: $I_{disc} \geq 1.15 \times I_{FLC}$.

  17. What horsepower relationship must a motor controller have to the motor it serves?

    The controller must have a horsepower rating at or above the motor's rating. (Exception: a stationary motor of 2 hp or less, 300 V or less, may use a general-use switch rated at least twice the motor FLC.)

  18. Per NEC 430.102, where must the motor controller disconnecting means be located relative to the controller?

    It must be located in sight from the controller location — visible and not more than 50 ft (15 m) away.

  19. How does the NEC define the phrase “in sight from” (or “within sight”)?

    The equipment is visible from one another and is not more than 50 ft (15 m) apart.

  20. What two capabilities/locations does the NEC require of the motor disconnecting means for the motor and driven machinery (430.102(B))?

    It must be capable of being locked in the open position and be located in sight from the motor location and the driven machinery (with limited exceptions where lockable provisions are allowed instead).

Show the other 30 Motors, HVAC, and Special Equipment flashcards
  1. For a hermetic refrigerant motor-compressor, what current value replaces horsepower/FLC for sizing, and where is it found?

    The rated-load current (RLC), marked on the equipment nameplate. Because the motor and compressor are sealed together, shaft horsepower cannot be measured.

  2. What is the branch-circuit selection current (BCSC) for a hermetic motor-compressor?

    A nameplate-marked current value, always equal to or greater than the marked RLC, used in place of the RLC for sizing conductors, disconnect, controller, and branch-circuit OCPD whenever it is the larger value (NEC 440.4(B)).

  3. When both RLC and BCSC are marked on a hermetic compressor, which value is used for sizing conductors and overcurrent devices?

    The larger of the two — use BCSC if it is greater than RLC; otherwise use RLC.

  4. Why are hermetic motor-compressor loads (Article 440) treated differently from standard motors (Article 430)?

    The motor and compressor are sealed within a common housing with no external shaft, so horsepower and standard FLC tables don't apply; the nameplate RLC (or BCSC) is used instead.

  5. What is the minimum ampere rating of the disconnecting means for a hermetic motor-compressor (NEC 440.12(A))?

    At least 115% of the nameplate rated-load current or branch-circuit selection current, whichever is larger.

  6. What is the maximum branch-circuit short-circuit/ground-fault OCPD for a single hermetic motor-compressor, and the absolute upper limit (NEC 440.22(A))?

    Not more than 175% of the RLC or BCSC (whichever is larger); if that is insufficient to start/hold the load, it may be increased to a maximum of 225%.

  7. If air-conditioning equipment is marked with a “maximum overcurrent protective device” (MOCP) rating, how must it be applied?

    The branch-circuit OCPD must not exceed the marked maximum value, even if calculations would otherwise permit a larger device.

  8. Per NEC 440.14, where must the disconnecting means for air-conditioning or refrigerating equipment be located?

    Within sight from and readily accessible from the air-conditioning or refrigerating equipment (it may be installed on or within the equipment).

  9. What minimum conductor ampacity is required for a single hermetic motor-compressor (NEC 440.32)?

    At least 125% of the RLC or BCSC, whichever is greater: $I_{conductor} \geq 1.25 \times I_{RLC/BCSC}$.

  10. How are conductors sized for a combination (multimotor) air-conditioning load per NEC 440.33?

    Ampacity at least 125% of the largest motor-compressor (or motor) load plus the sum of the rated currents of the other loads in the group.

  11. What does the nameplate “minimum circuit ampacity” (MCA) on HVAC equipment determine, per NEC 440.35?

    The minimum conductor ampacity required to supply the equipment; conductors are selected so their ampacity is at least the marked MCA.

  12. On a packaged HVAC unit nameplate marked with MCA and MOCP, which value sizes the conductors and which sizes the overcurrent device?

    MCA (minimum circuit ampacity) sizes the conductors; MOCP (maximum overcurrent protection) sets the maximum breaker/fuse rating.

  13. For multimotor HVAC equipment, what current value is used for each motor-compressor when computing the combination conductor and protection sizes?

    The rated-load current or branch-circuit selection current (whichever is greater) of each motor-compressor, plus the full-load currents of any other associated motors/loads.

  14. For a transformer over 600 V is excluded — for a transformer 600 V or less protected on the primary only with a primary current of $9$ A or more, what is the maximum primary OCPD percentage (Table 450.3(B))?

    125% of the rated primary current (with the next-higher-standard-size rule permitted when 125% does not correspond to a standard rating).

  15. Per Table 450.3(B), what primary-only OCPD percentages apply when primary current is less than $2$ A and when it is $2$ A to less than $9$ A?

    Less than $2$ A: up to 300%; $2$ A to less than $9$ A: up to 167% of rated primary current.

  16. For a 600 V-or-less transformer with both primary and secondary protection, what are the maximum percentages when the secondary current is $9$ A or more (Table 450.3(B))?

    Primary OCPD up to 250% of rated primary current and secondary OCPD up to 125% of rated secondary current.

  17. What does the “next higher standard rating” note for Table 450.3(B) allow?

    When the calculated percentage (e.g., 125%) of rated current does not correspond to a standard OCPD rating, the next higher standard rating is permitted.

  18. Does NEC 450.3 transformer overcurrent protection also protect the secondary conductors?

    No. Section 450.3 protects the transformer itself; the secondary (and primary) conductors require separate overcurrent/tap protection per 240.21 and 240.4.

  19. What is the formula for the full-load primary current of a single-phase transformer?

    $I = \dfrac{kVA \times 1000}{V}$, where $V$ is the primary line voltage.

  20. What is the formula for the line current of a three-phase transformer?

    $I = \dfrac{kVA \times 1000}{\sqrt{3} \times V_{line}}$.

  21. Calculate the primary full-load current of a 45 kVA, 480 V, three-phase transformer.

    $I = \dfrac{45000}{\sqrt{3} \times 480} \approx 54.1$ A.

  22. Calculate the secondary full-load current of a 45 kVA, three-phase transformer with a 208 V secondary.

    $I = \dfrac{45000}{\sqrt{3} \times 208} \approx 124.9$ A (about 125 A).

  23. Which NEC provisions govern sizing and protecting transformer secondary conductors, given that primary-side protection may not protect them?

    The transformer secondary conductor tap rules of NEC 240.21(C); primary OCPD generally does not protect secondary conductors (except a 2-wire single-phase or balanced 3-wire arrangement).

  24. What minimum conductor ampacity is required for the conductors supplying a capacitor (NEC 460.8(A))?

    At least 135% of the rated current of the capacitor: $I_{conductor} \geq 1.35 \times I_{cap}$.

  25. How must the overcurrent device for a capacitor be rated per NEC 460.8(B)?

    As low as practicable — an individual overcurrent device is required for each capacitor bank, except where the capacitor is connected on the load side of the motor running overcurrent (overload) device.

  26. What is the minimum ampere rating of a capacitor disconnecting means (NEC 460.8(C))?

    At least 135% of the rated current of the capacitor.

  27. When a capacitor is connected on the load side of a motor's running overload device, what are the conductor requirements (NEC 460.8(A))?

    A separate overcurrent device is not required, but the capacitor circuit conductors must have an ampacity at least 135% of the capacitor rated current and at least one-third the ampacity of the motor circuit conductors.

  28. Give the formula for the rated line current of a three-phase capacitor bank rated in kVAR.

    $I_{C} = \dfrac{kVAR \times 1000}{\sqrt{3} \times V_{line}}$.

  29. A three-phase capacitor draws a rated current of 18 A. What is the minimum required conductor ampacity?

    $1.35 \times 18 = 24.3$ A minimum conductor ampacity (NEC 460.8(A)).

  30. Compare how conductors are sized for a standard motor (Art. 430) versus a hermetic motor-compressor (Art. 440).

    Both use 125% of the governing current, but Article 430 bases it on the table FLC (from hp/voltage), while Article 440 bases it on the nameplate RLC or BCSC, whichever is greater.

Journeyman/Master Electrician License Exam Motors, HVAC, and Special Equipment FAQ

What is in the Journeyman/Master Electrician License Exam Motors, HVAC, and Special Equipment syllabus?

Journeyman/Master Electrician License Exam Motors, HVAC, and Special Equipment is split into 3 chapters: Motor Circuits (Article 430), Air Conditioning and Refrigeration (Article 440) and Transformers and Capacitors (Articles 450 and 460). Together they contain 10 topics and 19 sub-topics.

How many chapters are in Journeyman/Master Electrician License Exam Motors, HVAC, and Special Equipment?

3 chapters, containing 10 topics and 19 sub-topics. The largest chapter is Motor Circuits (Article 430), with 4 topics.

Are there flashcards for Journeyman/Master Electrician License Exam Motors, HVAC, and Special Equipment?

Yes — a 50-card Motors, HVAC, and Special Equipment deck, printed in full in the flashcards section of this page and available in the Examius app with spaced repetition. The free plan covers one exam of your choice, including its flashcards; Examius Pro, a one-time purchase, unlocks every other exam and deck.