🇺🇸 Journeyman/Master Electrician License Exam · subject
Journeyman/Master Electrician License Exam Low-Voltage, Communications, and Code Application Syllabus
The Low-Voltage, Communications, and Code Application syllabus for Journeyman/Master Electrician License Exam in full: 3 chapters, 9 topics and 18 sub-topics, every one listed below, plus 49 Low-Voltage, Communications, and Code Application flashcards with answers.
Low-Voltage, Communications, and Code Application syllabus: all 3 chapters
Expand any chapter to see its topics and sub-topics.
-
Class 1, 2, and 3 and Limited-Energy Circuits
3 topics- Power-Limited Circuits (Article 725)
- Class 2 and Class 3 power source limits
- Separation from power conductors
- Fire Alarm Systems (Article 760)
- Power-limited vs. non-power-limited circuits
- Survivability and cable types
- Communications and Coaxial Systems (Articles 800, 805, 820)
- Primary protector and grounding/bonding
- Cable listing markings (CMP, CMR, CM)
- Power-Limited Circuits (Article 725)
-
Exam Calculation Strategy
3 topics- Time Management for Open-Book Exams
- Tabbing and highlighting the code book
- Locating tables and articles quickly
- Common Calculation Question Types
- Multi-step service load problems
- Conduit fill and box fill combination problems
- Unit Conversions and Formula Recall
- Horsepower, kVA, and VA conversions
- Memorized constants (1.732, 1000, K values)
- Time Management for Open-Book Exams
-
Trade Practices, Safety, and Licensing Law
3 topics- OSHA and NFPA 70E Safety
- Lockout/tagout and approach boundaries
- Personal protective equipment and arc-flash categories
- Permits, Inspections, and the AHJ
- Role of the Authority Having Jurisdiction
- Plan review and rough-in vs. final inspection
- State and Local Licensing Rules
- Journeyman vs. master scope of work and supervision
- Continuing education and license renewal
- OSHA and NFPA 70E Safety
Journeyman/Master Electrician License Exam Low-Voltage, Communications, and Code Application flashcards — 49 questions with answers
Under NEC Article 725, what is the difference between a Class 1, Class 2, and Class 3 circuit?
Class 1 circuits are power-limited to 30 V and 1000 VA or remote-control/signaling up to 600 V (not power-limited as to current). Class 2 and Class 3 are power-limited circuits whose power source is limited by listed equipment; Class 2 limits both voltage and power for shock/fire safety, while Class 3 allows higher voltage (up to 150 V) with added protection against shock because more energy is permitted.
What NEC article covers power-limited and Class 1, Class 2, and Class 3 remote-control, signaling, and power-limited circuits?
Article 725.
For a Class 2 circuit power source, what are the typical maximum voltage and power limits (dry location, continuous AC source)?
A Class 2 source is generally limited to a maximum of 30 V and the power is limited so that the source cannot exceed roughly 100 VA (for a 30 V source, current limit around 5 A after considering overcurrent protection); these limits make Class 2 inherently safe from a fire and shock standpoint.
In Article 725, why can Class 2 and Class 3 conductors generally NOT be placed in the same cable or raceway as Class 1 or power/light circuits?
Because Class 2 and Class 3 circuits are power-limited and must be kept separated from non-power-limited (Class 1, electric light, power) conductors to prevent a higher-energy circuit from imposing dangerous voltage/energy onto the power-limited wiring. Separation (typically a barrier or a minimum spacing) is required unless specific exceptions are met.
What do the cable type abbreviations CL2, CL3, CL2P, CL2R, and CL2X designate in Article 725?
CL2/CL3 are Class 2/Class 3 cables. The suffixes indicate use rating: 'P' = plenum (highest fire rating), 'R' = riser (vertical runs between floors), 'X' = limited use (dwellings/raceways), and no suffix = general-purpose. Higher-rated cables may substitute for lower-rated ones (P > R > general > X).
What NEC article governs the installation of fire alarm systems?
Article 760.
In Article 760, what is the difference between a power-limited (PLFA) and non-power-limited (NPLFA) fire alarm circuit?
NPLFA circuits are not power-limited and follow Class 1 wiring rules (e.g., max 600 V), requiring more robust wiring methods. PLFA circuits are supplied by a listed power-limited source and follow Class 2/Class 3-style rules with smaller conductors and the FPL cable family.
What cable type designations are used for power-limited fire alarm circuits in Article 760?
The FPL family: FPL (general purpose), FPLR (riser), and FPLP (plenum). As with other cables, plenum-rated may substitute for riser, and riser for general purpose.
In a fire alarm circuit, what color is conventionally required (and often mandated by listing) for the cable jacket to identify it?
Power-limited fire alarm cable is conventionally identified with a red jacket, though the NEC itself focuses on marking/listing; red is the industry-standard color for fire alarm wiring.
What NEC article covers communications circuits (telephone and similar), including station wiring?
Article 800 (with Article 805 historically covering communications circuits; in modern NEC, Article 800 is the general communications wiring article).
What NEC article specifically covers coaxial cable distribution (community antenna television and radio, CATV)?
Article 820.
What do the communications cable types CM, CMR, CMP, CMX, and CMG indicate?
CM = communications general purpose, CMR = riser, CMP = plenum (highest fire rating), CMX = limited use (dwelling/raceway), CMG = general purpose (group rating). Substitution allows higher-rated cables in place of lower-rated ones: CMP > CMR > CMG/CM > CMX.
What are the coaxial cable type designations under Article 820 and their meanings?
CATV = general purpose, CATVR = riser, CATVP = plenum, and CATVX = limited use. The plenum type has the highest flame/smoke rating and can substitute downward.
Under Article 820, why and how must a coaxial cable shield be grounded (bonded)?
The outer conductive shield of coax must be bonded/grounded at the building entrance (primary protector or grounding block) to the building grounding electrode system, using a bonding conductor no smaller than 14 AWG, to safely conduct fault and lightning energy and equalize potential.
What is the general grounding-conductor maximum length goal for communications/coax bonding at the building entrance?
The primary protector/grounding conductor should be as short as practicable; the NEC commonly requires the grounding conductor run to be limited to about 20 ft for one- and two-family dwellings to minimize impedance during a surge.
What is a 'primary protector' in communications (Article 800) wiring and when is it required?
A primary protector is a listed surge/overvoltage protective device installed where communications conductors enter a building; it is required when the cable could be exposed to lightning, accidental contact with power conductors over 300 V, or power induction. It limits voltage to ground and protects equipment and people.
For an open-book trades exam, what is the recommended first time-management step before answering questions?
Budget your time by dividing total exam minutes by the number of questions to get an average pace (e.g., 4 hours / 80 questions = 3 minutes each), then answer easy questions first and flag/skip hard look-up questions to return to later.
On an open-book NEC exam, what tabbing/indexing strategy saves the most time?
Pre-tab your code book by article and major table, and rely heavily on the NEC Index and Table of Contents; practice finding articles by keyword so you can locate references in seconds rather than reading sequentially.
If a single open-book exam question is taking too long to look up, what is the best time-management decision?
Mark/flag it, make your best educated guess so no answer is blank (if there is no penalty for guessing), and move on; return to flagged questions only after completing all the ones you can answer quickly.
What is the formula for electrical power in a DC or resistive circuit, and what are common exam variants?
$P = V \times I$. Common variants from Ohm's law substitution are $P = I^{2}R$ and $P = \frac{V^{2}}{R}$.
Show the other 29 Low-Voltage, Communications, and Code Application flashcards
State Ohm's Law and its two algebraic rearrangements.
$V = I \times R$, rearranged as $I = \frac{V}{R}$ and $R = \frac{V}{I}$, where $V$ is volts, $I$ is amperes, and $R$ is ohms.
What is the formula for single-phase power including power factor, as used on the license exam?
$P = V \times I \times PF$, where $PF$ is the power factor (between 0 and 1). For apparent power, $S = V \times I$ in volt-amperes.
What is the three-phase power formula tested on the journeyman/master exam?
$P = \sqrt{3} \times V_{L} \times I_{L} \times PF$, where $V_{L}$ and $I_{L}$ are line voltage and line current, and $\sqrt{3} \approx 1.732$.
How do you calculate the full-load current of a single-phase motor or load given kVA?
$I = \frac{VA}{V} = \frac{kVA \times 1000}{V}$. For example, a 10 kVA single-phase load at 240 V draws $\frac{10000}{240} \approx 41.7$ A.
How do you calculate line current for a three-phase load given kVA and line voltage?
$I_{L} = \frac{kVA \times 1000}{\sqrt{3} \times V_{L}}$. For example, 30 kVA at 480 V: $\frac{30000}{1.732 \times 480} \approx 36.1$ A.
What is the conductor voltage-drop formula commonly used on the exam (single-phase)?
$V_{D} = \frac{2 \times K \times I \times L}{CM}$, where $K$ is the conductor constant (about 12.9 for copper, 21.2 for aluminum), $I$ is current, $L$ is one-way length in feet, and $CM$ is the conductor area in circular mils.
What constant $K$ values are used for copper and aluminum in voltage-drop calculations?
$K \approx 12.9$ ohm-circular-mils per foot for copper and $K \approx 21.2$ for aluminum (at typical operating temperatures).
What is the formula for the three-phase voltage drop on a feeder?
$V_{D} = \frac{\sqrt{3} \times K \times I \times L}{CM}$, where $L$ is the one-way length; note the multiplier is $\sqrt{3}$ for three-phase versus $2$ for single-phase.
What is the maximum recommended voltage drop per the NEC for branch circuits and for the combined feeder plus branch circuit?
The NEC recommends (informational, not mandatory) a maximum of 3% voltage drop on a branch circuit or feeder, and not more than 5% total for the combined feeder and branch circuit.
How do you convert between horsepower and watts for motor calculations?
$1 \text{ hp} = 746 \text{ W}$. So output power in watts $= hp \times 746$ (divide by efficiency to get input watts).
How do you convert kilowatts to BTU per hour, a common HVAC/load conversion?
$1 \text{ kW} = 3412 \text{ BTU/hr}$ (approximately). Multiply kW by 3412 to obtain BTU/hr.
What is the general area derating relationship between AWG sizes (the rule of thumb for circular mils)?
For every decrease of 3 AWG sizes the circular-mil area roughly doubles, and for every decrease of 10 AWG sizes the area increases about tenfold. Smaller AWG number = larger conductor.
How do you convert circular mils to square inches, and what is a circular mil?
A circular mil is the area of a circle 1 mil (0.001 in) in diameter: $A_{CM} = d_{mils}^{2}$ where $d$ is in mils. To convert, $1 \text{ in}^{2} \approx 1{,}273{,}240$ circular mils.
What is OSHA, and what is its relationship to electrical safety on the job?
OSHA (Occupational Safety and Health Administration) is the federal agency that sets and enforces workplace safety regulations (29 CFR 1910 for general industry, 1926 for construction). It adopts consensus standards like NFPA 70E for electrical safe work practices.
What is NFPA 70E and how does it differ from the NEC (NFPA 70)?
NFPA 70E is the Standard for Electrical Safety in the Workplace, covering safe work practices, arc-flash hazards, PPE, and the energized-work permit. The NEC (NFPA 70) covers safe installation of wiring and equipment. 70E protects workers; the NEC governs installations.
Under NFPA 70E, what is the 'electrically safe work condition' and the basic process to establish it (lockout/tagout)?
It is the state where equipment is de-energized and verified safe. The steps: identify all sources, interrupt the load and open disconnects, visually verify isolation, apply lockout/tagout, test for absence of voltage with a tester (and verify the tester before and after), and ground if needed.
In NFPA 70E, what is an arc-flash boundary?
The arc-flash boundary is the distance from a potential arc source at which the incident energy equals $1.2 \text{ cal/cm}^{2}$ (the onset of a second-degree burn on bare skin). Inside this boundary, arc-rated PPE is required.
What does NFPA 70E require before performing energized work that cannot be avoided?
An energized electrical work permit, justification that de-energizing is infeasible or creates greater hazard, a job safety/risk assessment, appropriate arc-rated PPE per the incident-energy analysis or PPE category tables, and qualified-person status.
What is an AHJ in the context of electrical permits and inspections?
The Authority Having Jurisdiction: the office, individual, or body (often the local electrical inspector or building department) responsible for approving equipment, materials, installations, and procedures and for enforcing the adopted code. The AHJ has final interpretation authority locally.
Why is an electrical permit typically required before starting work, and who usually pulls it?
A permit ensures the work is reviewed and inspected for code compliance and safety. The licensed electrical contractor (or, in some jurisdictions, the homeowner for their own residence) pulls the permit before work begins; doing work without a required permit can void approvals and incur penalties.
What is the typical sequence of electrical inspections on a new construction project?
Generally: (1) underground/trench inspection before backfill, (2) rough-in inspection after wiring is run but before walls are closed, and (3) final inspection after devices, fixtures, and the service are complete and energized-ready. Each must pass before proceeding.
What does it mean when the NEC says equipment must be 'listed' or 'labeled,' and who relates this to the AHJ?
'Listed' means a qualified testing lab (NRTL such as UL) has evaluated the product and it appears on a published list; 'labeled' means it bears that lab's mark. The AHJ relies on listing/labeling as evidence of suitability and may require it for approval.
What is the difference between a journeyman and a master electrician license?
A journeyman is licensed to perform electrical installation work, typically under the responsibility of a master, after completing an apprenticeship and required hours. A master electrician has additional experience and exam requirements, can pull permits, supervise journeymen/apprentices, and often own/operate a contracting business.
Who establishes electrician licensing requirements in the United States, and why do they vary?
Licensing is governed at the state and often local (city/county) level, not federally, so requirements (experience hours, exam content, reciprocity, continuing education) vary by jurisdiction. Always verify with the specific state licensing board.
What is reciprocity in electrical licensing?
Reciprocity is an agreement between states (or jurisdictions) to recognize each other's electrician licenses, allowing a licensed electrician to obtain a license in another participating state without retaking all exams, provided requirements are comparable.
What are typical experience-hour requirements before sitting for a journeyman vs. master electrician exam?
A journeyman typically requires about 8,000 hours (roughly 4 years) of supervised on-the-job experience plus schooling; a master typically requires an additional ~2,000+ hours (often 2 years as a licensed journeyman) before qualifying for the master exam. Exact hours vary by state.
On the licensing exam, how is the adopted NEC edition determined for a given jurisdiction?
Each state or local AHJ adopts a specific edition/cycle of the NEC (which updates every 3 years), sometimes with amendments. The exam is based on the edition currently adopted by that jurisdiction, so candidates must study the correct adopted edition.
What is the bonding conductor minimum size for grounding a communications or coax primary protector, and why does size matter?
Not smaller than 14 AWG copper. The bonding/grounding conductor must safely carry surge and fault currents to the grounding electrode; an adequately sized, short conductor keeps impedance low so dangerous voltages are quickly diverted to ground.
What is the key separation rule for Class 2/Class 3 (Article 725) and communications (Article 800) cables relative to electric light and power conductors?
Power-limited and communications conductors must be separated from electric light, power, Class 1, and NPLFA conductors by at least 2 inches unless the power conductors are in a raceway or metal-sheathed/UF cable, or a permanent barrier separates them. This prevents energy from the higher-power circuit reaching the low-voltage wiring.
Journeyman/Master Electrician License Exam Low-Voltage, Communications, and Code Application FAQ
What is in the Journeyman/Master Electrician License Exam Low-Voltage, Communications, and Code Application syllabus?
Journeyman/Master Electrician License Exam Low-Voltage, Communications, and Code Application is split into 3 chapters: Class 1, 2, and 3 and Limited-Energy Circuits, Exam Calculation Strategy and Trade Practices, Safety, and Licensing Law. Together they contain 9 topics and 18 sub-topics.
How many chapters are in Journeyman/Master Electrician License Exam Low-Voltage, Communications, and Code Application?
3 chapters, containing 9 topics and 18 sub-topics. The largest chapter is Class 1, 2, and 3 and Limited-Energy Circuits, with 3 topics.
Are there flashcards for Journeyman/Master Electrician License Exam Low-Voltage, Communications, and Code Application?
Yes — a 49-card Low-Voltage, Communications, and Code Application deck, printed in full in the flashcards section of this page and available in the Examius app with spaced repetition. The free plan covers one exam of your choice, including its flashcards; Examius Pro, a one-time purchase, unlocks every other exam and deck.